Marine Electrolysis Corrosion Blocker

MPS
Product ID:
44723
Availability:
Usually dispatches in 2-5 days
$579.95
(No reviews yet)
Condition:
New
Current Stock:
Adding to cart… The item has been added

The Marine Electrolysis Corrosion Blocker is a replacement sacrificial anode for the compatible marine application shown below.

Product information

  • The Maddox anode is an internationally accredited sacrificial anode for timber and fibreglass vessels. The patented composite alloy is closer than zinc in mV potential to the submerged metals found on most boats making it less aggressive on coatings and parts than the zinc equivalent.
  • Features & Benefits
  • 5000A fail safe rating
  • 67A continuous current rating
  • The MPS Electrolysis Blocker must be installed by a licenced Electrician. * The Electrolysis Blocker must be used in conjunction with a circuit breaker rated up to 16A max (minimum 5KA fault rated) and a 30mA residual current device. The diagram below shows the general arrangements for electrical supply to a vessel with blocker installed. Further information can be obtained in Appendix B of AS/NZS3004.2 The Electrolysis Blocker shall be connected into the supply protective earthing conductor before it connects to the boats earth system. It should be installed where there is protection from accidental access, good ventilation, as close as practical to the shore power inlet / distribution panel and behind the appliance inlet. Use the mounting slots on the Blocker to secure it. The Electrolysis Blocker is installed in series in to the earthing conductor, the Blocker is clearly labelled "Ship Earth" and "Shore Earth". The terminals of the Blocker should be treated as live parts. The information stickers provided must be affixed in plain view on the front of the distribution panel.
  • The MPS Electrolysis Blocker does not require service or maintenance as it contains no moving or serviceable parts. Boat owners are required to obtain an Electrical Warrant Of Fitness (EWOF) for all vessels with hard wired 240VAC electrical systems. MPS recommend inspection periodically by a licenced electrician to ensure earth terminal connections remain secure and the unit stays properly mounted. Electrolysis Blockers can be tested for performance and/or fault conditions by a qualified electrician using a multimeter. The MPS Electrolysis Blocker is designed and sold for the purpose of galvanic corrosion protection and must not be used for any other use.

Before ordering

Please compare the listed specifications and part number with your existing component. If you need help confirming compatibility, contact Jet Ski Parts Warehouse with your make, model, year and engine details.

12 months; covered by manufacturer against defects only